PVC DWV Fittings (AS NZS1260)

This specification covers PVC DWV Pipe Fitting for Drainage applications. This system is Intended for drainage applications where the operating temperature will not exceed 140°F.

Material Properties

 

Testing standards and certification of fittings

Tests:

Requirement/test standard

Initial type test

Self-monitoring

Third-party control

Appearance and surface

When viewed without magnification   the internal and external surfaces of the fittings were smooth, clean and   free from grooving, blistering, impurities, pores and other surface   irregularities likely to prevent conformity to the standard.

Yes

1 x per cavity per hour

1 x per year

Color

White color

Yes

1 x per cavity per hour

1 x per year

Dimension and tolerance

Acc. to Table7 & Table11

Yes

1x per 4 hour

1 x per year


附件\BS   13297.png


附件\BS   132911.png

Softening temperature

Acc. to EN 727, VST≥ 79°C

Yes

One per production shift

1 x per year

Effect of Heating

At 150°C, heating time: 30 min, no damage

Yes

One per production shift

1 x per year

Evaluated temperature cycling for application area B

Acc. to EN 1055, using test assembly b, figure 2. No leakage.

DN≤50:≤3mm

DN>50:≤0.05dn

Yes

No

At any new design or formulation

Marking

ERAR  EN 1329 尺寸  PVC-U  B

Yes

One per production shift

1 x per year